Book Now

Call Now

Contact Us

Book Now

Rockledge PA Heating Air Conditioning

Chud has provided air conditioning, heating, water heater, air quality and duct cleaning services to the residents of Rockledge, PA and the surrounding areas since 1970! We’re committed to providing first class air conditioning service to all of our clients.

We’re the AC experts. But don’t take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby Rockledge, PA heating and air company that specializes in air quality and duct cleaning.

Local Reviews
for Rockledge, PA

Chud Air Conditioning & Heating Rated 5.0 out of 5 stars based on 7 customer reviews

Our Reviews by City

Rydal, PA (16)


Map of Rockledge, PA 19046

Burke St




Review of Chud Air Conditioning & Heating

RockledgePA19046 40.085-75.095

Response from Chud Air Conditioning & Heating:

5 stars, thank you Gail!


Map of Rockledge, PA 19046

Great prompt service!!!!




Review of Chud Air Conditioning & Heating

RockledgePA19046 40.085-75.095

Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Gail. It truly means a lot to the Chud team!


Map of Rockledge, PA 19046

Excellent service




Review of Chud Air Conditioning & Heating

Primp and professional

RockledgePA19046 40.0825-75.0875

Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Dan & Florence. It truly means a lot to the Chud team!


Map of Rockledge, PA 19046

Great




Review of Chud Air Conditioning & Heating

Thanks. Shane got us up an running

RockledgePA19046 40.085-75.095

Response from Chud Air Conditioning & Heating:

5 stars, thank you Mark!


Map of Rockledge, PA 19046

Homeowner




Review of Chud Air Conditioning & Heating

RockledgePA19046 40.08-75.085

Response from Chud Air Conditioning & Heating:

5 stars, thank you Walter & Lauren!


Map of Rockledge, PA 19046

Excellent Service




Review of Chud Air Conditioning & Heating

RockledgePA19046 40.085-75.085

Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Susan. Everyone at Chud appreciates it.


Map of Rockledge, PA 19046

Great service




Review of Chud Air Conditioning & Heating

RockledgePA19046 40.085-75.085

Response from Chud Air Conditioning & Heating:

Susan, thank you for the 5 star review, were grateful you chose Chud!


Paul A.

Paul A.

Surveyed home with a Lennox SL280UH090 upflow gas furnace that is paired with a EL16036 style outdoor condensing unit. This system was installed around 2017. The homeowner advised that the installing contractor added return ductwork and also 10 years of maintenance and filters. The complaint is that the system is not able to keep up on days when there is high heat and humidity. Homeowner advised that overall the heating performance seems to be consistent. Chud will discuss this issue and make a decision about what the best solution would be. Chud will follow up with the homeowner and schedule a 2nd visit. N/C, survey.

Near Blake Ave, Rockledge, PA 19046
Shane A.

Shane A.

Replaced flame sensor on Lennox gas furnace. System is operating properly at this point. Manufacturer Lennox Model # ML180UH070E36B-54 Serial # 1718J23716 I DID NOT COLLECT PAYMENT

Near Burke Ave, Rockledge, PA 19046
Shane A.

Shane A.

System had no heat. The problem is a bad flame sensor. Client has heat, after I cleaned the flame sensor. but, does want the flame sensor replaced. I did not have that flame sensor on my truck. Will need to order. Manufacturer Lennox Model # ML180UH070E36B-54 Serial # 1718J23716

Near Burke Ave, Rockledge, PA 19046
Paul T.

Paul T.

Came out today to investigate a system that had a repair made on 12/26/22. Upon arrival the Goodman furnace was calling for 70° heat and it was 63 in the home. I reset the system and observed what happened when the system tried to start.the igniter came on and lit the burners. The burners were on for 3 seconds then went out. I observed the system try to start several times. I powered the system down and removed the flame sensor. The flame sensor is pretty beat up. I installed a new flame sensor to see if that would resolve the issue. I tested the system and it started without any issues. I cycled the system on and off multiple times to ensure that the system is operating properly. Each time the system fired up without any issues. The system is operating properly at this time.

Near Blake Ave, Rockledge, PA 19046
Frank B.

Frank B.

Customer called for no heat. We had a tech out recent to work on the system that didn’t make it onto service titan. The thermocouple was replaced by Chris on last visit. Needed to adjust the thermocouple due to it not sitting in the pilot assembly properly. Tested the system when completed. System is operating properly at this time. Per PA he said to charge for the EMS visit and the thermocouple. Collected for those 2 things today. No charge for return visit today.<br> Manufacturer Crown Model #AWI061SNLT1PSU Serial #PIPLFT000308839

Near Robbins Ave, Rockledge, PA 19046
Christian C.

Christian C.

Came out to assess no heat call. Upon arrival I observed system light and than immediately shut off. I removed flame sensor cleaned carbon build up and readjusted flame sensor when placing back in unit. System started up properly and I observed it run its cycle. Home has heat at this time. Model # GMH80703ANAB Serial # 0706065849

Near Blake Ave, Rockledge, PA 19046
Frank B.

Frank B.

Performed preventative maintenance for gas furnace. Merv 11 Filter was replaced in the spring and won’t be due till spring 2023. Cleaned the burners, flame sensor and burner box. Made sure inducer port is clear. Inspected all the electrical components. Confirmed proper high and low voltages. Tested the operation of the fan, stage 1 heat and stage 2 heat from the communicating thermostat. Inspected the gas piping going into the furnace. Performs a combustion analysis on the furnace. System is operating at 84% efficiency with a CO level of 20ppm. Tested the amp draw of the blower and inducer. Both were operating within the manufacturer spec. System is operating properly at this time. Model #SL280UH090V36B-04 Serial #5916K02434

Near Robbins Ave, Rockledge, PA 19046
Shane A.

Shane A.

Went to a new heat call. Driving to the job the fan was blowing after testing I realize a hot surface igniter was bad. Replaced it system is operating properly at this point. M#TG8S080B12MP11A s#W1K2182993

Near Burke Ave, Rockledge, PA 19046
Paul A.

Paul A.

Did I prevent an im tenance on the Lenox 80% unit. Did a combustion test Seo level was 2202 level was 12. During the maintenance I clean the flame sensor also cleaned out the burner rack and blower motor housing. Also did amp readings on the inducer motor and blower motor service or within range of furnace specs. Part of the chimney was falling apart where the flue pipe meet the wall, I used silicone to seal the gap. Also switch the 16 x 20 x 1 filter. System is operating properly at this point. M#G60UHV-36B-090-07 s#5907K30440 customer prepaid

Near Burke Ave, Rockledge, PA 19046
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 2 bedroom. Single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!

Near Winchester Ave, Rockledge, PA 19046
Paul T.

Paul T.

Came out today to check the temperature of the hot water for the first floor. I took a temperature reading from the kitchen sink and got a reading of 121°F. I set the hot water heater for the Lowest setting and removed some of the hot water. Took a second reading using 2 different temp probes and the readings were 100°F and 101°f. I observed the hot water heater to see if it would fire up to heat the water. The hot water heater is maintaining the temperature of 100°f. The system is operating properly at this time. Bill out per office.

Near Park Ave, Rockledge, PA 19046
Paul T.

Paul T.

Checked hot water heater for 1st floor and second floor. Checked all water connections for leaks and rust. Checked the gas connections to ensure that there are no gas leaks. The electronic components for both systems are operating properly at this time. Both systems are operating properly at this time. Performed preventative maintenance for a crown boiler system model #Awi061snlt1psu, serial #Piplft000331063. This system is for the first floor only. Removed and cleaned carbon off of the flame sensor. Cleaned out the burners and burner box. The water pressure is at 12 psi. The limit is set for 180. The expansion tank is in good condition. I observed the system starting normally. The circulator pump is operating properly. Performed a combustion analysis test and got the following readings, o2 is at 13%, co is at 15 ppm and the system is operating at 84% efficiency. The system is operating properly at this time. Performed preventative maintenance for a crown boiler system model #Awi037

Near Park Ave, Rockledge, PA 19046
Sebastian R.

Sebastian R.

Performed preventative maintenance on Lennox AC system. Changed MERV 11 16x25x5 air filter provided by the customer. Tested evaporator coil pan and condensate line for proper drainage. Temperature split is at 21° with a supply air temperature of 45°. This unit has an accurate refrigerant charge. Compressor- 5.7 RLA Condenser fan motor- 0.7 FLA. Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the upcoming season.

Near Robbins Ave, Rockledge, PA 19046
Anthony  C.

Anthony C.

Performed preventative maintenance on Goodman Gas Furnace. Replaced 14x25x1 air filter given from the customer. Cleaned and inspected burners, flame sensor and blower compartment. Completed a combustion analysis and the CO PPM was 5. System is working properly at this time and is ready for the season!

Near Blake Ave, Rockledge, PA 19046
Frank B.

Frank B.

Performed preventative maintenance on the Lennox gas furnace. Checked all controls and components related to heating per manufacturer's recommendations. Cleaned burners, flame sensor and burner compartment. checked the temperature rise of 51°. Performed a combustion analysis on the furnace. System is operating at 83% efficiency with a CO level of 16ppm. Customer supplies own filters. (16x20x1) Customer has repair agreement which they prepaid. System is operating properly at this time. Customer asked for a duct cleaning quote. Attached to the invoice is the estimate for duct cleaning.

Near Burke Ave, Rockledge, PA 19046
Keith R.

Keith R.

Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years.

Near N Sylvania Ave, Rockledge, PA 19046
Frank B.

Frank B.

Performed preventative maintenance for gas furnace. Cleaned the burners, flame sensor and burner box. Made sure inducer port is clear. Inspected all the electrical components. Inspected the gas piping going into the furnace. Performs a combustion analysis on the furnace. System is operating at 84% efficiency with a CO level of 22ppm. Tested the amp draw of the blower and inducer. Both were operating within the manufacturer spec. System is operating properly at this time.

Near Robbins Ave, Rockledge, PA 19046
Keith R.

Keith R.

Performed dryer vent cleaning. Dryer vent, , duct, flex hose, lint trap and rear of dryer are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years.

Near Park Ave, Rockledge, PA 19046
Jonathan C.

Jonathan C.

Return visit to finish heating portion of install. Ran 2 inch vent pipe out of basement. Ran 1/2 inch gas line from water heater location to furnace with 2 new 1/2 inch gas valves. Tested heat, heat is operating properly at this time.

Near N Sylvania Ave, Rockledge, PA 19046
Paul A.

Paul A.

Installed warranty thermostat through Lennox.

Near Robbins Ave, Rockledge, PA 19046
Matthew M.

Matthew M.

Day 1 complete. AC portion is installed and running. Will return to complete heating portion.

Near N Sylvania Ave, Rockledge, PA 19046
Paul T.

Paul T.

Performed preventative maintenance for a Coleman system. Replaced the air filter (16x20x1) checked drain pan and drain line for any possible clogs. Checked the evaporator and condenser coils for buildup. Checked all electrical components needed for air conditioning. The temp split is at 19. The system is operating properly at this time and is ready for the summer season.

Near Jarrett Ave, Rockledge, PA 19046
Paul A.

Paul A.

Preseason tune-up on Lennox HVAC system. Customer replaces their own 16x20x1 air filter. Tested drains by pouring water through evaporator coil pan. Verified R-410a freon/refrigerant charge is correct by checking temperature split. Inspected all electrical components and tested amperage. Discussed IAQ and left pricing for air duct cleaning. System is ready for the season. N/C, has R/A.

Near Burke Ave, Rockledge, PA 19046
Paul A.

Paul A.

Pre-season tune-up performed for Lennox HVAC system. (Customer supplied) MERV 11 filter replaced. Drain line cleared and primed. Verified R-410a refrigerant charge is correct. Voltage and amperage readings completed for electrical components. Chud will check on warranty for the iComfort WiFi thermostat. Homeowner reports a few “glitches” with thermostat. System is ready for the summer. N/C, FWI.