We’re the AC experts. But don’t take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby Phoenixville, PA heating and air company that specializes in air quality and duct cleaning.
Local Reviews
for Phoenixville, PA
Our Reviews by City
Great service
Wilburn - Phoenixville, PA 19460
Quite knowledgeable
Response from Chud Air Conditioning & Heating:
Wilburn, thank you for the 5 star review!
Great Service!
Michele - Phoenixville, PA 19460
Response from Chud Air Conditioning & Heating:
Thank you for the 5 star review Michele! The Chud team appreciates it.
Keith arrived on time. The duct cleaning was explained and executed well. Cleanup was excellent and care was taken with the house and furniture.
Wilburn - Phoenixville, PA 19460
Good professional experience
Response from Chud Air Conditioning & Heating:
Wilburn, thank you for the kind words and 5 star review. The Chud team appreciates it.

Paul A.
Did a preventative maintenance on a gas furnace. During the maintenance I clean the flame sensor and I also cleaned out the trap for the high-efficiency furnace. And I made sure that the drain was draining. Also I did a combustion test the PPM was 28 and the O2 was nine. I did an amp check on the inducer motor and the blower motor which both me the furnace specs. Cleaned out the burner box and the blower motor housing customer changed filters. Filter size 3(14x14x1) 2(20x20x1) m#59SC2D080E17–16 s#2620A59266 customer paid for a 1 year maintenance agreement for a Air-conditioning tuneup in 2023 and customer used the heater maintenance today for her maintenance agreement System is operating properly at this time

Paul A.
Homeowner has Bradford White S#WE45219528 (50 gallon gas direct vent) water heater. Existing ST-5 expansion tank. Water pressure per my gauge is 75 PSI. Per expansion tank sizing chart the ST-5 is acceptable for this application based on pressure and the temperature setting. Homeowner has water heater set at “factory setting” which is about 110 degrees to 120 degrees. Any setting above 160 degrees would require the ST-12 for 50 gallon. Preventative maintenance ac system. Homeowner replaces own (20x20x1). He has (3) filter grilles in the home. He maintains filters on a schedule. Coil inspection, gravity drain draining properly, amperage check on ac related components and 410a refrigerant charge verified correct. 17.2 degree delta T reading. Left IAQ recommendation. Has had duct cleaning performed by Chud and heater maintenance.

Keith R.
Performed air duct cleaning and sanitation. All vents, ductwork and blower motor are all clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!

Paul A.
Performed Air Duct Cleaning Service on a 2 Bedroom, 1 system unit. Customer has 2 thermostats for one system which is why there was a confusion on how many systems there were. All vents are clear of dust and debris at this time. Thank you for your business!

Keith R.
Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!

Keith R.
Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time l unit is functioning properly at this time. Recommend duct cleaning every 2-3 years. Customer opted out of dryer vent cleaning. Thank you for your business!

Keith R.
Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years. Performed dryer vent cleaning, dryer vent, duct and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your

Keith R.
Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years. Thank you for your business!

Keith R.
Performed air duct cleaning and sanitation on a 3 system house. All vents and ductwork are clear of dust and debris at this time. All units are functioning properly at this time. Recommend duct cleaning every 2-3 years. Thank you for your business!this was free with install.

Jonathan C.
Performed maintenance on high efficiency furnace in attic. Customer had already changed all three filters in the ceiling upon my arrival. Cleaned flame sensing rod and burner compartment. Performed combustion analysis and furnace is venting properly with no carbon monoxide. Unable to install humidifier due to furnace being located in attic in un conditioned space. Tested and cycled furnace, furnace is operating properly at this time.

Jonathan C.
Could not install humidifier on attic system in un conditioned space

Keith R.
Performed air duct cleaning and sanitation on a 2 bedroom house. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years. Performed dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!