Book Now

Call Now

Contact Us

Book Now

New Hope PA Heating Air Conditioning

Chud has provided air conditioning, heating, water heater, air quality and duct cleaning services to the residents of New Hope, PA and the surrounding areas since 1970! We’re committed to providing first class air conditioning service to all of our clients.
We’re the AC experts. But don’t take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby New Hope, PA heating and air company that specializes in air quality and duct cleaning.

Local Reviews
for New Hope, PA

Chud Air Conditioning & Heating Rated 5.0 out of 5 stars based on 9 customer reviews

Our Reviews by City

Rydal, PA (16)


Map of New Hope, PA 18938

Prompt, professional service




Review of Chud Air Conditioning & Heating

Paul T. was on time, efficient and professional addressing a leak in the humidifier unit.

New HopePA18938 40.355-74.96

Response from Chud Air Conditioning & Heating:

Gloria & Mary, thank you for the 5 star review, we are grateful that you chose Chud.


Map of New Hope, PA 18938

Paul was skilled and professional on the job.




Review of Chud Air Conditioning & Heating

New HopePA18938 40.335-75.0025

Response from Chud Air Conditioning & Heating:

Diane, thank you for leaving Chud a 5 star review!


Map of New Hope, PA 18938

Great service!




Review of Chud Air Conditioning & Heating

friendly, did a great job, explained everything to me. great experience!

New HopePA18938 40.3425-75.0025

Response from Chud Air Conditioning & Heating:

Felix, thank you for the kind words and 5 star review!


Map of New Hope, PA 18938

good service




Review of Chud Air Conditioning & Heating

New HopePA18938 40.3-75.04

Response from Chud Air Conditioning & Heating:

Lorel, thank you for the 5 star review, we are grateful that you chose Chud.


Map of New Hope, PA 18938

Professional Service




Review of Chud Air Conditioning & Heating

The duct cleaning was done quickly and efficiently!

New HopePA18938 40.355-74.96

Response from Chud Air Conditioning & Heating:

5 stars, thank you Gloria & Mary! The Chud team appreciates it!


Map of New Hope, PA 18938

Excellent, Great Service




Review of Chud Air Conditioning & Heating

New HopePA18938 40.355-74.96

Response from Chud Air Conditioning & Heating:

5 stars, thank you Gloria & Mary!


Map of New Hope, PA 18938

Ms




Review of Chud Air Conditioning & Heating

John did major work on my heater last year and did an excellent job. He was just as thorough and efficient this time with the preventative maintenance. He showed me what to watch out for and keep an eye on. He is courteous and very pleasant to have work here. You all have an A-One employee.

New HopePA18938 40.3675-74.9525

Response from Chud Air Conditioning & Heating:

Sherry, we’ll make sure to pass your kind words along to John, who we know will be delighted to read your comments.


Map of New Hope, PA 18938

On time service




Review of Chud Air Conditioning & Heating

New HopePA18938 40.3525-74.97

Response from Chud Air Conditioning & Heating:

We're glad to hear we met your expectations Susan. Thank you for the 5 star review!


Shane A.

Shane A.

Cleared out vynl tubing.Condensate pump shut unit down cleared drain and bottom of the pump. System is operating properly at this time. Manufacturer Lennox Model # EL296UH090XV60C-03 Serial # 5912H28991

Near W Riverwoods Dr, New Hope, PA 18938
Paul A.

Paul A.

Waiting for wife’s decisions

Near Muirfield Ct, New Hope, PA 18938
Paul A.

Paul A.

Did not want to make decision

Near Lurgan Rd, New Hope, PA 18938
Paul T.

Paul T.

Came out today to inspect a leaking high efficiency Lennox furnace model #EL296UH090XV60C-03, serial #5912H28991. Upon arrival the homeowner showed me a puddle of water under the back of the furnace. I powered the system down and removed the access panels. There are no signs of water in or near the inducer motor or anywhere near the blower motor. The leak is isolated to the back of the system. The humidifier sits on the back of the system. I opened the humidifier and noticed that the humidifier pad was covered in this clear gel. This humidifier was not serviced by chud this past year. I recommend performing humidifier service and the homeowner agreed. I replaced the #35 water panel and cleaned out the housing and drain line. I powered the system back up and tested for proper operation and leaks. The system is operating properly at this time.

Near W Riverwoods Dr, New Hope, PA 18938
Paul T.

Paul T.

Performed preventative maintenance for a Lennox heat pump model #XP14-036-230-10, serial #5814L07199. Upon arrival I powered the system down and removed the access panels. The evaporator coil’s are clean and in good condition. Tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. Checked all electrical connections to ensure that they are secure and in good condition. Dispatch stated that the homeowner replaced the air filter a couple weeks ago however it is very dirty so I installed a new 20x20x1 air filter. I re installed the access panel and called for heat. The system started without any issues. The blower motor amp draw is 1.8. The heat pump coils are clean and in good condition. The heat pump amp draws are .98 for the fan and 8.7 for the compressor. The refrigerant pressures are within normal range. The system is operating properly at this time.

Near 641 Silverwind Court West, New Hope, PA 18938
Paul T.

Paul T.

Performed preventative maintenance for a Trane heat pump model #4TWR5030H1000AB, serial #220947T74F. I powered the system down and removed the access panels. The evaporator coil’s are clean and in good condition. Tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. The homeowner just replaced the air filter size 16x20x1. Clean out any dirt or debris in the air handler. I powered the system back up and called for heat. The supply temp is at 134°f. The condenser coil’s are clean and in good condition. The condenser amp draws are .69 for the fan and 9.56 for the compressor. The refrigerant pressures are within normal range. The system is operating properly at this time. FWI per office.

Near Darien Way, New Hope, PA 18938
Paul T.

Paul T.

Performed preventative maintenance for a high efficiency Lennox furnace model #EL296UH090XV60C-03, serial #5912H28991. I powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor and cleaned out the burners and burner box. The homeowner will replace the air filter when it is delivered Merv16 16x25x5. Checked the pressure switch for clogs and tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Performed humidifier service for a healthy climate humidifier. I removed and replaced the old #35 water panel and cleaned out the tray and housing. Checked all electrical connections to ensure that they are secure and in good condition. I powered the system back on and called for heat. Took a combustion analysis test and received the following readings, o2 is 11.3% and the co levels are 14ppm. The inducer motor amp draw is .48 and the blower motor amp draw is 5.10. The supply temp is 124

Near W Riverwoods Dr, New Hope, PA 18938
Frank B.

Frank B.

Performed preventative maintenance for high efficiency furnace. Customer replaced the air filter (16x25x1). Inspected all the electrical components. Confirmed proper high and low voltages. Tested the amp draw from the blower and inducer. Both are operating within the manufacturer spec. Customer stated the system still has a vibration noise but this time instead of end of cycle it’s during the beginning of the cycle. Made adjustments to vibration Dampening mounts to get rid of the inducer wheel rubbing. If this comes back or continues the ECM inducer assembly will need replacement. The end of cycle vibration noise has been solved with the new blower motor last year. Performed a combustion analysis on the furnace. System is operating at 95.3% efficiency with a CO level of 11ppm. Cleaned the burners, flame sensor and burner box. System is operating properly at this time.

Near W Ferry St, New Hope, PA 18938
Jonathan C.

Jonathan C.

Flip flopped zone heads and proper thermostats are controlling proper zones of the house.

Near Stoney Hill Rd, New Hope, PA 18938
Paul T.

Paul T.

Came out today to replace warranty parts. After repair further diagnostics were needed. Upon inspection I found a faulty external low water cut off. The new Weil-McLain boilers have them built in. I wired the system back to its factory settings and called for heat. The system started right without any issues. I observed the system hitting the temperature limit and shut down. There is no need for an external low water cut off since it is built in. The system is operating properly at this time. No charge part of install.

Near Stoney Hill Rd, New Hope, PA 18938
Paul T.

Paul T.

Use a small furnco fitting or rubber dishwasher fitting and extend black tubing with 3/4" PVC and run neatly away from the home. Add a standard float switch in the evaporator coil drain pan if there is currently not one there. There is no charge for this work per RC as this was a new installation completed by Chud. N/C, WARRANTY WORK.

Near Darien Way, New Hope, PA 18938
Paul T.

Paul T.

Came out today for a system condensation issue. Upon inspection I found that the Trane system has a gravity drain that runs through the wall and out to the condenser. The condenser is sitting on a slab of concrete that is not level. This is causing the condensation to run back to the house and rott the wood. See photos. I was able to place a small piece of vinyl tubing into the condensation drain to re direct the water as a temporary solution. I will get with PA and figure out a plan to permanently address this issue. Also the system should have an ez trap installed as a form of water protection. No charge the system was installed in March of this year.

Near Darien Way, New Hope, PA 18938
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 4 bedroom dual system house. All vents and ductwork are clear of dust and debris at this time. Both systems are functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed a first floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business! sent customer a recommendation for a Merv cabinet there is ample space for an install.

Near Bellflower Ln, New Hope, PA 18938
Matthew M.

Matthew M.

Installed new Weil-Mclane boiler. Adapted to gas line. Installed 4 new Honeywell thermostat. Installed new zone control installed new switch and low voltage wire from zone board to previous taco zone valve installed new auto fill an air separator, also installed new expansion tank. And adapted to supply and return piping. Reused flu pipe. During start up propane gas valve is faulty. Paul will need to order a new one and schedule a day to come back.

Near Stoney Hill Rd, New Hope, PA 18938
Keith R.

Keith R.

Performed a 2 nd floor dryer from the inside using brushes and nikro vac. Unable to locate vent. It appears to flow into the soffit. Duct, flex hose and lint trap are all clear of lint and debris at this time . Performed first floor dryer vent cleaning. Dryer vent duct and flex hose are free of lint and debris at this time. Both dryers are functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for business!

Near Lower Mountain Rd, New Hope, PA 18938
Sebastian R.

Sebastian R.

Performed preventative maintenance on Lennox heat pump system. Customer replaced MERV 20x20x4 air filter prior to us coming out. Tested evaporator coil pan and condensate line for proper drainage. Temperature split is at 20° with a supply air temperature of 50°. This unit has the correct refrigerant charge. Compressor-5.2 RLA Condenser fan motor-0.4 FLA . These readings are both within the amperage rating for this unit. System is operating properly at this time and is ready for the upcoming season.

Near Silverwind Ct W, New Hope, PA 18938
Matthew M.

Matthew M.

Completed heavy duty filter rack 16x20x1 relocation from front of unit to bottom of unit. Tested system in heat and ac mode. Customer stated system noise sounds quieter than it did before modification. Cycled and tested, system working properly at this time. NO CHARGE.

Near Darien, New Hope, PA 18938
Paul A.

Paul A.

Addressed blower noise on Trane heat pump system. Discussed and emailed photos to Trane technical support team in real time. They advised to put the front door back on over the blower compartment, and test pulling return air from the bottom. The test proved to be a lot quieter. There will still be some noise from the air turbulence.

Near Darien, New Hope, PA 18938
Jonathan C.

Jonathan C.

Installed new Trane heat pump an air handler. Project included new pad whip an disconnect. Adapted to lineset drain an high voltage and low voltage. Adapted to supply an return. Installed new heat pack. Used wall mount to hang air handler installed new thermostat. Filter size 16’’x16’’x1’’ system is tested and working properly at this time.

Near Darien, New Hope, PA 18938
New Hope, PA - Installed new Trane heat pump an air handler. Project included new pad whip an disconnect. Adapted to lineset drain an high voltage and low voltage. Adapted to supply an return. Installed new heat pack. Used wall mount to hang air handler installed new  thermostat. Filter size 16’’x16’’x1’’ system is tested and working properly at this time.  New Hope, PA - Installed new Trane heat pump an air handler. Project included new pad whip an disconnect. Adapted to lineset drain an high voltage and low voltage. Adapted to supply an return. Installed new heat pack. Used wall mount to hang air handler installed new  thermostat. Filter size 16’’x16’’x1’’ system is tested and working properly at this time.
Frank B.

Frank B.

Performed preventative maintenance for heat pump system. Customer replaced the 2- 16x20x1 filters. Inspected all electrical components. Components are operating best they can considering the age. System had a heat rise of 26° heat pump only. System uses 6 30amp buss fuses. Wires have some charging in the heat kit but is still operational. Heat kit is a 15kw. Inspected the heat pump. Coil is clear with no major buildup of debris. Amp draw for the compressor and fan motor are on the higher end of the rated load amperage. As stated system is operational but is very inefficient and noisy. Recommend replacement due to age and parts will be hard to come by if repairs are needed. Most parts for this system have been discontinued. Air handler is 49 years old and heat pump is 21 years. Customer would like a quote for replacement. Referred estimate to RC.

Near Darien, New Hope, PA 18938
Keith R.

Keith R.

performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years. Thank you for your business and have a wonderful holiday!

Near W Riverwoods Dr, New Hope, PA 18938
Paul T.

Paul T.

Came out today for a leaking furnace. Upon inspection I found that the condensate pump was filled with water but was not pumping the water out. The pump was filled with debris and it was blocking the float from lifting up to pump out the water. I replaced the pump with a new 115v proselect. I also had to clear a clog out of the drain line using a flexible brush. I found some pieces of red carpet in the drain pan of the evaporator coil. Recommend performing duct cleaning to ensure debris doesn’t fall into the drain pan and create another clog. The system is operating properly at this time.

Near W Riverwoods Dr, New Hope, PA 18938
Paul T.

Paul T.

Performed preventative maintenance for a high efficiency Lennox furnace. Observed the system starting normally. Took a combustion analysis test and got the following readings, o2 is at 9.8%, co is at 3ppm and the system is operating at 94% efficiency. Observed the system shut down normally. Removed and cleaned carbon off of the flame sensor. Cleaned out the drain trap. Cleaned out the burners and burner box. Checked all electrical components needed for heating. Replaced the air filter Merv 16. Performed humidifier service. Removed the old water panel and replaced it with a new water panel. Cleaned out the housing and drain. Installed the panel and tested the system. Both systems are operating properly at this time.

Near W Riverwoods Dr, New Hope, PA 18938
Paul T.

Paul T.

Preventative maintenance for a Lennox heat pump. Performed humidifier service.

Near Silverwind Ct W, New Hope, PA 18938
Paul A.

Paul A.

Installed a new variable speed blower motor and blower wheel. This is due to a loud vibration noise that is getting worse. Previous diagnostic by FB and video from the homeowner helped provide diagnostic for this intermittent issue. The furnace is working properly and no noises are present upon completion of repairs.