Book Now

Call Now

Contact Us

Book Now

Erdenheim PA Heating Air Conditioning

Chud has provided air conditioning, heating, water heater, air quality and duct cleaning services to the residents of Erdenheim, PA and the surrounding areas since 1970! We’re committed to providing first class air conditioning service to all of our clients.

We’re the AC experts. But don’t take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby Erdenheim, PA heating and air company that specializes in air quality and duct cleaning.

Local Reviews
for Erdenheim, PA

Chud Air Conditioning & Heating Rated 5.0 out of 5 stars based on 6 customer reviews

Our Reviews by City

Rydal, PA (16)


Map of Erdenheim, PA 19038

OUTSTANDING!!




Review of Chud Air Conditioning & Heating

5 Star Very Professional

ErdenheimPA19038 40.1-75.205

Response from Chud Air Conditioning & Heating:

Michael, thank you for the 5 star review!


Map of Erdenheim, PA 19038

Great service - thank you




Review of Chud Air Conditioning & Heating

ErdenheimPA19038 40.095-75.21

Response from Chud Air Conditioning & Heating:

You are welcome Sean! Thank you for choosing Chud.


Map of Erdenheim, PA 19038

Great Service




Review of Chud Air Conditioning & Heating

Paul was excellent. He is very knowledgeable and was very informative!

ErdenheimPA19038 40.1-75.205

Response from Chud Air Conditioning & Heating:

5 stars, thank you Michael!


Map of Erdenheim, PA 19038

Paul T CHUDD Service




Review of Chud Air Conditioning & Heating

Excellent

ErdenheimPA19038 40.1-75.205

Response from Chud Air Conditioning & Heating:

5 stars, thank you Michael. The Chud team appreciates it!


Map of Erdenheim, PA 19038

Great technician, quick response




Review of Chud Air Conditioning & Heating

Frank showed up within the window of time expected. Checked our entire system, and gave some needed advice on our system and the thermostat which are only a couple of years old.

ErdenheimPA19038 40.09-75.2125

Response from Chud Air Conditioning & Heating:

So glad Frank was able to help you out. Thank you for the 5 star review Lisa!


Map of Erdenheim, PA 19038

Great service




Review of Chud Air Conditioning & Heating

Always professional with high quality service

ErdenheimPA19038 40.0975-75.2125

Response from Chud Air Conditioning & Heating:

Rob, thank you for the 5 star review!


Keith R.

Keith R.

Unable to perform duct cleaning at this time due to suspected microbial growth. Presented some solutions to prevent a recurrence but customer was not interested at this time. Customer is in contact with Paul Davis and we will return for the duct cleaning after the testing results.

Near Longfield Rd, Erdenheim, PA 19038
Shane A.

Shane A.

Their was a bird in the inducer motor. After taking the bird out system worked fine. Did a combustion test it was ppm was 90. System should be replaced due to age it’s from 1999. Unit is operating properly at this time. m#UGPH-10EAMER s#FD5D302F510003753

Near Glendalough Rd, Erdenheim, PA 19038
Shane A.

Shane A.

M#SLP98UH090V60C-02 s#5911E22770 did a maintenance on furnace. Customer changed the pure air kit, but the led light was not working after inspection the led bulb was loose. Also, cleaned the flame sensor and checked the HSI. Did a combustion test everything is operating safely. Did amp check on inducer and blower motor. System is operating properly at this point. M#LF24-75A-5 s#5911E22770 did a maintenance on a ceiling mounted gas furnace. System has no filter, did a amp check on the inducer motor and blower motor and both met the specs of the unit. Also cleaned the flame sensor and checked the spark ignition an cleaned it off. System is operating properly at this point

Near Atwood Rd, Erdenheim, PA 19038
Paul A.

Paul A.

Did a preventive maintenance on a gas furnace. During the maintenance I clean the flame sensor check the hot surface igniter. Cleaned out the burner box and the blower motor housing. Also did an amp check on the inducer motor and the blower motor which both meet the furnace specs. And tightened and made sure all electrical connections were secure. Did a humidifier maintenance as well during the maintenance I switched out the number 35 panel and wipe down the whole entire humidifier then made sure it was working properly and draining then I made sure that the condensate pumping was working properly which it was. Did a combustion test the parts per million were 22 and the O2 was nine. System is operating properly at this point. M#TG8S080B12MP11 s#W1N7386172 changed out 16 x 25 x 1 filter.

Near Avondale Rd, Erdenheim, PA 19038
Frank B.

Frank B.

Performed preventative maintenance for standard gas furnace. Upon arrival customer stated that he went to turn it on and he heard the inducer come on but no flame. As I started my diagnosis I found the pressure switch sticking causing the unit not to light. Replaced the pressure switch with a compatible.30 WC pressure switch I had available on the truck. Tested the system upon completion. System is operating properly at this time. Confirmed proper high and low voltages. Cleaned the burners, flame sensor and burner compartment. Customer replaces the 16x25x1 filter. Performed a combustion analysis on the furnace. System is operating at 78.9% efficiency with a CO level of 29ppm. System is fairly old and would recommend replacing in the near future but is operating as it should at this time.

Near Glendalough Rd, Erdenheim, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Lennox furnace model #G60uhv-36b-090-07, serial #5907l02959. Powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor, cleaned out the burners and burner box. Replaced the air filter size 16x25x5 homeowner supplied. Checked all electrical connections to ensure that they are secure and in good condition. Tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. I powered the system up and called for heat. Took a combustion analysis test and received the following readings, 02 is at 15% and the co levels are at 4ppm. The inducer amp draw is at .63 and the blower motor amp draw is at 4.2. The supply temp is at 135°F. The system is operating properly at this time.

Near Shippen Rd, Erdenheim, PA 19038
Sebastian R.

Sebastian R.

Performed preventative maintenance on Lennox AC system. PAK is due for a change out in September. Customer installs PAK himself. Tested evaporator coil pan and condensate pump for proper drainage. Temperature split is at 20° with a supply air temperature of 40°. This unit has an accurate refrigerant charge. Compressor- Condenser fan motor- . Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the upcoming season. Lennox condenser- S#5811C02635 M#XC21-036-230-06 Filter- PAK (customer installs himself)

Near Atwood Rd, Erdenheim, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Lennox system. The evaporator coil’s are clean and in good condition. Tested the drain pan, drain line and condensate pump with several cups of hot water. Replaced the Merv16 air filter that was severely clogged. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. I observed the system starting normally. The amp draw for the blower motor is at 2.6. The temperature split is at a 19. The condenser coil’s are clean and in good condition. The amp draws for the condenser are .66 for the fan and 5.7 for the compressor. The refrigerant pressures are 105/218. These are normal readings for 410-A refrigerant within ambient temperature of 57°. The system is operating properly at this time.

Near Shippen Rd, Erdenheim, PA 19038
Paul A.

Paul A.

Maintenance just completed about a month ago. Issue is related to 2nd floor zone. Verified proper water pressure. Limit setpoint at 180. Identified each zone. 2 zones have analog (mercury) style t-stats, and the 2nd floor has a Honeywell 6000 digital programmable. We tested the zones to verify all valves are opening and closing properly. Radiators are not air bound. 1 in master does not work, which is likely due to settling of the home or piping/or sediment build up. Keeping lower setpoints on both 1st floor analog t-stats and a slightly higher setpoint for 2nd floor will improve the issue. Left 2 optional recommendations and emailed to homeowner. Replace automatic water fill and replace all (3) t-stats to Honeywell T1 style.

Near Glendalough Rd, Erdenheim, PA 19038
Paul A.

Paul A.

Survey for booster fans. Explained benefits of adding a single zone ductless system as well. Homeowner will decide based on discussing with his wife. Chud will follow up after the holidays. N/C, survey/estimate.

Near Shippen Rd, Erdenheim, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Weil-McLain boiler. I observed the system starting normally. I took a combustion analysis test and got the following readings, 02 is at 17%, co is at 12ppm and the system is operating at 78% efficiency. Upon arrival the water pressure was at 5psi. The auto fill was not operating due to the water shut off valve was in the closed position. I filled the system to 15psi. The circulator pump is operating normally and the limit is set for 180F. All 3 zone valves are operating properly and in good condition. The system is operating properly at this time.

Near Glendalough Rd, Erdenheim, PA 19038
Paul A.

Paul A.

Performed preventative maintenance on Coleman Gas Furnace and Aprilaire Humidifier. Homeowner stated he had already replaced 16x25x1 air filter. Completed combustion analysis and CO PPM was 0. Cleaned and inspected burners, flame sensor and blower compartment along with verifying proper amperage on the motors. Cleaned and replaced water panel #35 for humidifier. Customer stated that he will not prepay for spring maintenance and that he will contact us to schedule if he wants appointment. Both systems are in good condition and ready for the season!

Near Avondale Rd, Erdenheim, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Ruud furnace. Observed the system starting normally.took a combustion analysis test and got the following readings, o2 is at 12%, co is at 35 and the system is operating at 81% efficiency. Observed the system shut down normally. Removed and cleaned carbon off of the flame sensor. Cleaned out the burners and burner box. Checked all electrical components needed for heating. Amp draws for the blower motor and inducer are both within normal range. Replaced the air filter 16x25x1. The system is operating properly at this time.

Near Glendalough Rd, Erdenheim, PA 19038
Frank B.

Frank B.

Performed preventative maintenance for 2 gas furnaces. The main house system is a high efficiency furnace and the garage system is a standard efficiency ceiling hung unit. Inspected all the electrical components. Tested the amp draw of the blowers and inducers. All were operating within the manufacturer specs. Customer replaces the pure air kit for the main house system. The unit in the garage doesn't take a filter. Made sure all exhaust and drain fittings had tight screws due to some loosening from operation vibration. Performed a combustion analysis on the furnaces. Home system is operating at 94.6% efficiency with a CO level of 18ppm. Garage system had a heat rise of 85°. Basement system had a temp rise of 52°. Both systems are operating properly at this time.

Near Atwood Rd, Erdenheim, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Lennox furnace. Observed the system starting normally. Took a combustion analysis test and got the following readings, o2 is at 14%, co is at 2ppm and the system is operating at 81% efficiency. Observed the system shutting down normally. Removed and cleaned carbon off of the flame sensor. Cleaned out the burners and burner box. Checked all electrical components needed for heating. Replaced the air filter Merv16. Checked all electrical components needed for heating. The system is operating properly at this time.

Near Shippen Rd, Erdenheim, PA 19038
Paul A.

Paul A.

Replaced existing bypass humidifier with an Aprilaire 600M with humidistat. Tested for proper operation. Explained winter setpoint of 35%-40%. This is sufficient for majority of homeowners. Humidifier will only run when heater is running and indoor humidity is below the desired setpoint.

Near Brookside Rd, Erdenheim, PA 19038
Paul A.

Paul A.

Performed annual maintenance on Lennox high efficiency gas furnace. Replaced filter, cleaned burners and blower compartment. Verified proper amperage on all controls. Performed humidifier service, replaced #35 water panel. Distribution tray and tubing are corroded. I did soak the tray in bleach/water, however we will follow up with a price to replace the tubing and tray or quote to replace the existing bypass humidifier due to potential for leaking. Otherwise, system is safe and ready for the season.

Near Brookside Rd, Erdenheim, PA 19038
Paul T.

Paul T.

Came out today for a no AC call. During inspection I found that the blower was not operating and it was due to a loose connection in the thermostat. The temperature split is was at 1. I connected my gauges and noticed that the system was empty of refrigerant. I also found that the capacitor rated at 40+5 was only giving off 25+3. I replaced the capacitor and explained to the homeowner that the system is completely empty and most likely has a large leak. I recommend replacing the unit but the homeowner declined. I then recommend charging the system and adding super seal so we can attempt to find the leak in the future. The homeowner stated that he just wanted the capacitor and the refrigerant. I explained that we can charge the system but can not guarantee that it won't leak. I added 5 lbs of 410-A and the temperature split is now at 19. The system is operating at this time.

Near Glenway Rd, Erdenheim, PA 19038
Frank B.

Frank B.

Performed preventative maintenance for high efficiency heating system and certified the whole system for proper/safe operation. Replaced the filter. Inspected all the electrical components. Cleaned the burners, burner box and flame sensor. Performed a combustion analysis on the furnace. System is operating at 95.3% efficiency with a CO level of 10ppm. Made sure all tubing was clear from the collector box and pressure switches. Helped customer better understand the setting with the smart thermostat. System is working at maximum performance and is in safe operating condition.

Near Bethlehem Pike, Erdenheim, PA 19038
Keith R.

Keith R.

Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years. Performed dryer vent cleaning. Dryer vent, flex hose, lint trap and rear of dryer are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years.

Near Longfield Rd, Erdenheim, PA 19038
Frank B.

Frank B.

Performed preventative maintenance for a single split system for cooling. Replaced the standard air filter. Inspected all the electrical components. Tested the temperature split between the supply and return. System is operating with a 19° differential. Made sure drain piping was clear and the pump was operational. Tested the amp draw from the compressor, blower and fan motor. All were operating within the manufacturer spec. System is operating at maximum performance at this time.

Near Bethlehem Pike, Erdenheim, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Lennox system. Checked drain pan and drain line for any possible clogs. Checked to ensure that the condensate pump is operating. Checked the evaporator and condenser coils for buildup. The customer recently replaced the Merv11 air filter. Checked all electrical components needed for air conditioning. The temperature split is at 20. The system is operating properly at this time and is ready for the summer season.

Near Longfield Rd, Erdenheim, PA 19038
Paul T.

Paul T.

Performed preventative maintenance for a Lennox system. Checked drain pan and drain line for any possible clogs. Checked condensate pump to make sure it was operational. Checked the evaporator and condenser coils for buildup. Replaced Merv16 (20x25x5) air filter that the customer supplied. Checked all electrical components needed for air conditioning. The temperature split is 20+ The system is operating properly at this time and is ready for the summer season.

Near Shippen Rd, Erdenheim, PA 19038
Paul T.

Paul T.

Arrived at the customers house to perform preventative maintenance for a Lennox air handler system. The customer let me know that the system was not working. After checking everything I came to the conclusion that there is something wrong with the board and or blower.

Near Glendalough Rd, Erdenheim, PA 19038
  • HomeAdvisor Top Rated Service
  • HomeAdvisor Elite Service Award - Chud Air-Conditioning, Heating, Refrigeration Co., Inc.
100% Customer Satisfaction Guaranteed