Book Now

Call Now

Contact Us

Book Now

Blue Bell PA Heating Air Conditioning

Chud has provided air conditioning, heating, water heater, air quality and duct cleaning services to the residents of Blue Bell, PA and the surrounding areas since 1970! We’re committed to providing first class air conditioning service to all of our clients.

We’re the AC experts. But don’t take our word for it. Check out our reviews and find out why your neighbors consider us to be their nearby Blue Bell, PA heating and air company that specializes in air quality and duct cleaning.

Local Reviews
for Blue Bell, PA

Chud Air Conditioning & Heating Rated 5.0 out of 5 stars based on 7 customer reviews

Our Reviews by City

Rydal, PA (16)


Map of Blue Bell, PA 19422

Great service on our Aprilaire




Review of Chud Air Conditioning & Heating

Blue BellPA19422 40.185-75.3

Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Felicia. It truly means a lot to the Chud team!


Map of Blue Bell, PA 19422

Excellent




Review of Chud Air Conditioning & Heating

Blue BellPA19422 40.185-75.3

Response from Chud Air Conditioning & Heating:

5 stars, thank you Felicia!


Map of Blue Bell, PA 19422

Great experience




Review of Chud Air Conditioning & Heating

Blue BellPA19422 40.1775-75.2425

Response from Chud Air Conditioning & Heating:

Nicole, thank you for leaving Chud a 5 star review!


Map of Blue Bell, PA 19422

Helpful and informative technician




Review of Chud Air Conditioning & Heating

Blue BellPA19422 40.1475-75.2975

Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Josh & Ilana, everyone at Chud appreciates it!


Map of Blue Bell, PA 19422

Friendly & Efficient




Review of Chud Air Conditioning & Heating

Frank Breen was on time, performed the heat pump fall checkup with confident expertise, and was very courteous. He also re-hung my sliding doors to my air handler closet. Me having just had hernia surgery a couple weeks ago - I was physically unable to do it alone. Thank you Frank!

Blue BellPA19422 40.1525-75.2625

Response from Chud Air Conditioning & Heating:

Glenn, we’ll make sure to pass your kind words along to Frank, who we know will be delighted to read your comments.


Map of Blue Bell, PA 19422

Excellent customer care




Review of Chud Air Conditioning & Heating

Paul was on time, careful about not tracking in dirt on his feet or oil onto driveway. He explained everything he did clearly and advised me on some easy maintenance procedures.

Blue BellPA19422 40.14-75.25

Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Linda. It truly means a lot to the Chud team!


Map of Blue Bell, PA 19422

Great Service Using Chud for 25 years




Review of Chud Air Conditioning & Heating

I have been using Chud sinnce 1997. Their service is outstanding!

Blue BellPA19422 40.155-75.29

Response from Chud Air Conditioning & Heating:

Janice, thank you for working with us for so many years. We look forward to working together for many years to come.


Shane A.

Shane A.

Installed a new distribution tray. System is test and draining properly at this point. M#600m

Near Abbey Ct, Blue Bell, PA 19422
Shane A.

Shane A.

All work on this invoice will have a 60-day warranty Customer had no heat no heat. His thermostat was blank. Condensate pump safety switch turned the unit off. I repiped the ac unit and humidifier to the French drain. System is tested and operating properly at this time. SL280UH110V60C04 Model # 5916M12019 Serial #

Near Birkdale Dr, Blue Bell, PA 19422
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 3 bedroom single system home. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed a Rooftop dryer vent cleaning. Dryer vent, duct, flex duct and lint trap are all clear of lint and debris at this time. Dryer is functioning properly and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!

Near Abbey Ct, Blue Bell, PA 19422
Paul T.

Paul T.

Came out today to perform humidifier service on a Aprilaire 600 series humidifier. Upon arrival the homeowner stated that the humidifier is currently leaking. I found a fault in the waist water removal system. I provided the homeowner with several repair options. The homeowner chose the band aid repair. Chud will have to order the parts and reach out to the homeowner with a repair date. Humidifier service could not be performed today since the humidifier is not operational. Maintenance will be performed after the repair.

Near Abbey Ct, Blue Bell, PA 19422
Paul A.

Paul A.

Scheduled for march 2nd 11:30-12:00

Near Abbey Ct, Blue Bell, PA 19422
Keith R.

Keith R.

Performed an air duct cleaning and sanitation on a 4 bedroom single system home. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed a rooftop dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!

Near Regency Cir, Blue Bell, PA 19422
Frank B.

Frank B.

Came out to provide an estimate for dryer vent rerouting. Dryer vent currently vents into the basement into a water catch basket. Customer would like hard piped dryer vent going to the outside upon inspection the best way to run this dryer vent from inside to out is through the basement. we will go out an older plywood sealed up window. This old window is underneath the back deck and is easily accessible. I crawled under to inspect the exiting location. This run is approximately 20 feet total from dryer to output. Will need to add a 4 foot length of flex as well due to the dryer being in a corner. This will need to be attached so dryer can be moved in and out of its space. Install standard vent hood with built in pest barricade. 2 techs will be needed. Attached is the pricing for this install (parts and labor). No charge for today’s survey.

Near Pemberton Rd, Blue Bell, PA 19422
Keith R.

Keith R.

Performed a first floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!

Near Valley Rd, Blue Bell, PA 19422
Paul A.

Paul A.

Preventative maintenance inspection/tune up on a Trane high efficiency gas furnace. Combustion analysis CO 9 PPM, O2 9.7%. Replaced a 16x25x1 filter with a company supplied filter. Verified amperage and voltage readings. Burners are slightly rusted, flame sensor was rusted and worn. Replaced flame sensor on site to avoid nuisance no heat issues based on age/condition of part. Verified proper drainage for exhaust condensation. Overall, system in fair condition for a 12 year old system. Average life expectancy is about 15 years. System is currently operating properly at this time. Trane M#TUH2C100A9V4VAB, S#10044PTC7G. Filter-16x25x1. ***Optional quote provided to replace an existing bypass humidifier with a new Aprilaire 600 series humidifier. Includes new humidistat.*** Existing humidifier has not been in use and is not recommended to use at this time.

Near Glenn Ln, Blue Bell, PA 19422
Paul A.

Paul A.

Did they preventative maintenance on a gas furnace. During the maintenance I clean the flame sensor And cleaned out the burner box and the blower motor housing. Did a combustion test and the ppm was 30 and the O2 what is 8.8. Changed out the 16 x 25 x 1 filter. It’s an amp check on the inducer motor and blower motor which both met the furnace specs. Customer stayed at one day last week he had to go downstairs and check on the heater because the blower motor was making a very loud noise. Arriving today I did not hear no loud noise and the amperage on the blower motor is in range. System is operating properly at this point M#EL280UH110P60C-01 s#5912F32483

Near Inverness Dr, Blue Bell, PA 19422
Paul T.

Paul T.

Performed preventative maintenance for a Lennox heat pump system model #CBX32MV-048-230-6-07, serial #1616B27399. Upon arrival the homeowner stated that when she went to turn the heat on for the first time she received an error code and called chud. While on the phone with the technician the system corrected itself. The homeowner also stated that they had a brief power outage before she turned the system on for the first time. I called for heat to observe the system starting. The system fired up a ran without any issues. I let it run for about 15 minutes then shut it back down. I removed the access panels to inspect the air handler. The evaporator coil’s are in good condition. Tested the drain pan and drain line with several bottles of water. The blower wheel is a bit dirty and should be cleaned. Checked all electrical connections to ensure that they are secure and in good condition. I powered the system back up and called for heat. The system started right up. The blower motor amp dr

Near Silo Cir, Blue Bell, PA 19422
Keith R.

Keith R.

Performed a Second floor dryer vent cleaning. Dryer vent, duct,flesh hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!

Near Dogwood Ln, Blue Bell, PA 19422
Frank B.

Frank B.

Completed preventative maintenance for heat pump system. System operates on 410A refrigerant. Temp split in HP of 33.5 degrees. Tested electric heat 15kw. Had a heat rise of 51°. Both capacitors in the indoor (rated 370/15mfd)and outdoor (rated 440. 45/5mfd) unit are in good shape. Outdoor contactor is functioning properly. Tested Outdoor fan motor, compressor and blower for proper amperage. Blower operating at 2.5A, outdoor fan motor .6A and compressor at 6.7A. Confirmed proper high and low voltages. Found no damaged or melted wires within the air handler. Filter was replaced recently by customer. System is operating properly at this time. Model #XP14-036-230-03 Serial #5811B18053

Near Village Cir, Blue Bell, PA 19422
Paul A.

Paul A.

Preventative maintenance on Lennox gas furnace. System is equipped with all IAQ products including MERV 16 filter, bypass humidifier and Reme Halo whole house air purifier. Inspected burners/burner compartment, pulled/clean flame sensor, amperage checked on inducer and indoor blower. Reset iComfort thermostat correctly on sub-base. Homeowner advised that vinegar was added to pump to prevent build-up and does that on a monthly basis. Installed customer supplied MERV 16-16x25x5 air filter and installed company supplied #35 water panel. System is currently operating properly and ready for the season. Lennox Gas Furnace M#EL296UH090XV48C-04, S#5912K39242. Filter-MERV 16-16x25x5. #35 water panel during fall service. Optional quote left to have air duct cleaning done. Last service was 08/20/2020.

Near Crystal Ct, Blue Bell, PA 19422
Paul A.

Paul A.

Completed preventative maintenance on Coleman furnace. On arrival noticed that the #35 panel from last year appeared new. Tested humidifier and found the saddle valve was defective. Replaced the saddle valve on site by draining the water heater halfway and installed new valve. Re-lit water heater pilot. Inspected all fittings for water leaks. Tested humidifier drain line. Installed customer supplied MERV 11-16x25x5 filter. Installed Chud supplied #35 water panel. System is now operating properly and ready for the season. Coleman M#TM9V080B12MP11CA, S#W1K6001398. Filter-16x25x5 MERV 11, bypass humidifier #35 panel.

Near Jamie Ct, Blue Bell, PA 19422
Paul A.

Paul A.

Came out today to address a condensate pump issue. Homeowner pointed out a spot in the 3/8” vinyl tubing that had a visible clog. Cleared line. Re-connected the tubing to the pump and tested the pump via having homeowner turn on the heat and run the humidifier. The tubing is clear. Homeowner did want to have maintenance services performed at this time. Homeowner changes their own 16x25x4 MERV 11 air filters. Pump is working properly and 3/8” vinyl tubing is clear. York furnace (1st floor) S#W1F4819439. Homeowner advised that they were offered 10% senior discount which was applied to the invoice.

Near Sawgrass Dr, Blue Bell, PA 19422
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 3 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed a 2nd floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!

Near Tulip Tree Ct, Blue Bell, PA 19422
Paul T.

Paul T.

Performed preventative maintenance for a high efficiency Trane system model #4ttx5048a1000aa , serial #101358nn2f. The evaporator coil’s are clean and in good condition. Tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. Replaced the air filter size 16x25x1. The blower motor amp draw is within normal range. The temperature split is at a 20. The condenser coil’s are clean and in good condition. The condenser amp draws are 1.8 for the fan and 11.6 for the compressor. The refrigerant pressures are within normal range for the temperature outside today. The system is operating properly at this time.

Near Glenn Ln, Blue Bell, PA 19422
Keith R.

Keith R.

Performed air duct cleaning and sanitation on a 3 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!

Near Fetlock Ln, Blue Bell, PA 19422
Paul T.

Paul T.

Performed preventative maintenance for a high efficiency Lennox system model #XC17-036-230, serial #5812H03498. Upon arrival I noticed that there was a puddle of water under the system. I shut the system down and removed the evaporator coil access panel. I found the drain pan had a large piece of insulation blocking the drain line. I removed the insulation and tested the drain pan drain line and condensate pump with several cups of hot water to ensure that there were no leaks or clogs. The evaporator coil’s are clean and in good condition. Air filter was replaced in the fall Merv11. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. Turned the system on and the blower motor amp draw is at 4.7. The temperature split is at 20. The condenser coil’s are clean and in good condition. The condenser amp draws are 1.3 for the fan and 8.1 for the compressor. The refrigerant pressures are within normal range for the temperature outs

Near Crystal Ct, Blue Bell, PA 19422
Paul T.

Paul T.

Came out today for a thermostat Issue. Upon inspection I found that the shut off switch at the top of the stairs was in the off position. The homeowner just had movers in the home today bringing furniture up from the basement. The movers must have hit the switch. I turned the switch to the on position and the system started right up. The system is operating properly at this time.

Near Birkdale Dr, Blue Bell, PA 19422
Matthew M.

Matthew M.

Completed Lennox evaporator coil, and Condenser installation. Replaced thermostat with Honeywell T6. Adapted to existing lineset (flushed), electrical, and ductwork. Outside replaced disconnect box, whip, and pad. Re wrapped suction lines inside and out.

Near Holstein Ct, Blue Bell, PA 19422
Sebastian R.

Sebastian R.

Came out for a AC maintenance, upon arrival the condenser was not running. After performing a voltage test 220 volts were found at the contactor. When manually pushing in the contactor the compressor would attempt to run but the condenser fan motor would not run. The fan motor has the proper amperage but being it’s a 23 year old motor it has now inoperable. System is 23 years old, a recommendation to upgrade to new equipment is being made to the customer. Pictures of the existing unit were taken and the customer will now be transferred to our salesperson. Lennox condenser- S#589-832-9763 M#C2646FC1 Filter size- MERV 16x25x5

Near Holstein Ct, Blue Bell, PA 19422
Paul A.

Paul A.

Performed preventive maintenance on a Coleman heat pump system. The outdoor unit as well as the indoor coil were checked. All findings were within the specs of the manufacturer’s recommendations. The homeowner replaced a 20x20x1 air filter before our arrival. There was an 18 degree delta T. The system was operational for during the service without any faults. The system is ready for the season. Coleman Heat Pump M#TH4B4821SA S#W1B7405023

Near Cathcart Rd, Blue Bell, PA 19422
Sebastian R.

Sebastian R.

Return to replace the UV bulb for a Honeywell single bulb UV device customer prepaid for bulb with the maintenance.